PERSONALITY NAME: TRACK
OUTPUT FOLLOWS STATE OF INPUT DEVICE: YES
APPLICABLE PERSONALITY MODIFIERS: SOFT START
SWITCH DEBOUNCE TIME: 10 milliseconds (standard, can be customized)
Functions Controlled
Typical Input Switch Type
Toggle switch, push button momentary switch, key-Lock switch, or momentary lever switch.
Personality Description
This is the most common used personality. The function describes a condition where an output node on a POWERCELL™ Control Unit follows the state of a switch located on the Input node of the MASTERCELL™ Input Unit. When you turn the switch to it’s “ON” position the output node turns ON (applies power to the circuit load). When you turn the switch “OFF” the output node on the POWERCELL™ Control Unit turns “OFF” (removes power from the circuit load).
Functional Relationship
ONE-to-ONE and MANY-to-ONE